Hammond Series | 1447S | EN4DCS all versions | |
---|---|---|---|
ABB Controls |
Disconnect |
Flange operated switch (fusible or non-fusible) | |
Shaft: 8-12” dp enclosures, use DSFHS-12; 16” dp enclosures, use DSFHS-17 | |||
Handle: DSFHN-HS4 | Handle: n/a | ||
Door Hardware: n/a | |||
Circuit Breaker |
Circuit breaker: ABB | ||
Operating Mechanism: see ABB chart | |||
Shaft: 8-12” dp enclosures, use K7FHD-S12; 16” dp enclosures, use K7FHD-S17 | |||
Handle: K7FHD-HS4 | Handle: n/a | ||
Door Hardware: n/a | |||
Allen Bradley | 1494U Flange Disconnect Switch |
Disconnect switch and operating mechanism: Bulletin 1494U | |
Handle: Bulletin 1494U-W1 | Handle: n/a | ||
Connecting rod: 8-10” dp enclosures, use 1494U-RA1; 12-16” dp enclosures, use 1494U-RA2 |
|||
(except for Hammond part # 1447S46L12, use 1494U-RB2 (2)) | |||
Trailer fuse block kit (if required): Bulletin 1494U | |||
Fuse kit (if required) | |||
Line and load connectors (if required) | |||
Door Hardware: n/a | |||
1494U Flange Circuit Breaker | Circuit breaker: C-H Westinghouse | ||
Operating mechanism: Bulletin 1494U | |||
Handle: Bulletin 1494U-W11 | Handle: n/a | ||
Connecting rod: 8-10” dp enclosures, use 1494U-RA1; 12-16” dp enclosures, use 1494U-RA2 |
|||
Door Hardware: n/a | |||
Cutler Hammer | Type C361 Disconnect Switch |
Disconnect switch and operating mechanism | |
Handle: C361-H2 or H4 | Handle: n/a | ||
Door Hardware: n/a | |||
Type C371 Circuit Breaker |
Circuit breaker: C-H Westinghouse | ||
Operating mechanism | |||
Handle: 150 amp, use C371H2 or H4; 250-600 amp, use C371H6 or H8 | Handle: n/a | ||
Door Hardware: n/a | |||
C-H Westinghouse Circuit Breaker w/FlexShaft | Circuit breaker | ||
Complete Flex-Shaft handle mechanism | |||
Door Hardware: n/a | |||
General Electric | Type STDA Flange Disconnect Switch |
Disconnect switch Type QMR or QMW | |
Handle: STDA1X | Handle: n/a | ||
Fuse kit (if required) | |||
Variable depth operating mechanism | |||
Door Hardware: n/a | |||
Type STDA Flange Circuit Breaker |
Circuit breaker | ||
Handle: STDA1X | Handle: n/a | ||
Variable depth operating mechanism | |||
Door Hardware: n/a | |||
Circuit Breaker w/SpectraFlex | Circuit breaker | ||
Flange Mt. Handle: 150-600 amp, use STDA1X; SK1200, use STDA3X | Handle: n/a | ||
Breaker mounted mechanism. | |||
Operating cable | |||
Door Hardware: n/a | |||
I-T-E Siemens | Max-Flex Flange Disconnect Switch |
Disconnect switch: MCS | |
Fuse Kit (if required) | |||
Handle: Flange mount FHOHS4 | Handle: n/a | ||
Switch operator mechanism | |||
Operating cable (standard 36.0”) | |||
Door Hardware: n/a | |||
Max-Flex Flange Circuit Breaker | Circuit breaker | ||
Pressure wire connectors | |||
Handle: Flange mount FHOH4 | Handle: n/a | ||
Circuit breaker operator mechanism | |||
Operating cable: Standard 36" | |||
Door Hardware: n/a | |||
Square D | Class 9422 Disconnect Switch |
Disconnect switch and operating mechanism 9422 | |
Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 | Handle: n/a | ||
Door Hardware: n/a | |||
Class 9422 Circuit Breaker |
Circuit breaker | ||
Operating mechanism: Class 9422 | |||
Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 | Handle: n/a | ||
Door Hardware: n/a | |||
Class 9422 “T” Disconnect Switch w/ cable mechanism |
Disconnect switch and operating mechanism 9422, Type T | ||
Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 | Handle: n/a | ||
Cable mechanism: Class 9422 CFT_O - 3, 5, or 10 foot | |||
Door Hardware: n/a | |||
Circuit Breaker w/cable mechanism | Circuit breaker: Square D | ||
Handle: 1447SN4 use A-1 or A-2; 1447SN4SS use A-2 | Handle: n/a | ||
Door Hardware: n/a |
Space Occupied by Disconnect
Note: | "K" | = | 8.62 | when | "C" | = | 8.00 |
"K" | = | 11.62 | when | "C" | = | 12.00 | |
"P" | = | Wiring Space |
Disconnects will occupy space on panel shown by dimensions "K", "L" and "M".
Wiring space "P" is available when disconnect is installed in the enclosure.
*The disconnect information and space occupied tables based on data supplied by disconnect manufacturer’s bulletins. Hammond Manufacturing not responsible for dimensional accuracy.
ABB Controls
ABB Controls Disconnect Switches (Flange Mounted Operators)
Fits Enclosure Depth | ABB Switch Number |
Amp | Fuse Class |
Space Occupied | When K=8.62 |
When K=11.62 |
|||
---|---|---|---|---|---|---|---|---|---|
8 | 12 | Rating | Fuse Clip | L | M | P | P | ||
• | • | OETL-NF30-F | 30A | No Fuse | — | 4.45 | 3.78 | 10.28 | 13.28 |
• | • | OETL-NF60-F | 60A | No Fuse | — | 4.86 | 3.78 | 10.09 | 13.09 |
• | • | OETL-NF100-F | 100A | No Fuse | — | 4.86 | 4.78 | 9.53 | 12.53 |
• | • | OETL-NF175-F | 175A | No Fuse | — | 7.30 | 6.49 | 7.28 | 10.28 |
• | • | OETL-NF200-F | 200A | No Fuse | — | 7.36 | 7.28 | 7.28 | 10.28 |
• | • | OESA-F30J6-F | 30A | 30A-600V | J | 4.28 | 6.58 | 8.61 | 11.61 |
• | • | OESA-F60J6-F | 60A | 60A-600V | J | 4.28 | 6.26 | 8.61 | 11.61 |
• | • | OESA-F100J6-F | 100A | 100A-600V | J ¹ | 6.54 | 7.65 | 8.17 | 11.17 |
200A ² |
¹ J type fuse clips are standard. If 600 V Type “T” fuse clips are desired order T type fuse adaptor kit.
² 200 A available by using non-fusible 200A switch and a trailing fuse block. (consult ABB) ABB Controls Circuit Breaker (Flange Mounted Operators)
Fits Enclosure Depth | Amp | Space Occupied | When K=8.62 | When K=11.62 | ||||
---|---|---|---|---|---|---|---|---|
8 | 12 | ABB Mechanism | Rating | Fuse Type | L | M | P | P |
• | • | FHD-M | 150A | D | 6.92 | 3.94 | 9.17 | 12.17 |
• | • | FHF-M | 15A-225A | E/Q | 5.98 | 4.23 | 7.72 | 10.72 |
• | • | FHF-M | 225A | Frame | 7.44 | 4.23 | 7.72 | 10.72 |
• | FHJ-M | 400A | J | 9.71 | 5.62 | — | 8.77 | |
• | FHM-M | 600A | L | 8.28 | 11.26 | — | 8.28 | |
• | FHM-M | 800A | M | 10.11 | 11.26 | — | 7.87 |
Fits Enclosure Depth | ISOMAX Circuit Breaker |
Amp Rating |
Operating Mechanism |
Fuse Type |
Space Occupied | When K=4.75 |
When K=7.09 |
||
---|---|---|---|---|---|---|---|---|---|
8 | 12 | L | M | P | P | ||||
• | • | S1N100TL | 100A | K2FHD-M | S1 | 5.30 | 4.60 | 9.13 | 12.13 |
• | S3N150TW | 150A | K3FHD-M | S3 | 6.67 | 5.02 | 11.53 | ||
• | S3N225TW | 225A | K3FHD-M | S3 | 6.67 | 5.02 | 11.53 | ||
• | S4N250BW | 250A | K4FHD-M | S4 | 8.45 | 5.02 | 10.00 | ||
• | S5N400TW | 400A | K5FHD-M | S5 | 8.45 | 6.40 | 10.00 | ||
• | S6N600TW | 600A | K6FHD-M | S6 | 8.33 | 10.00 | 9.33 | ||
• | S6N800TW | 800A | K6FHD-M | S6 | 8.33 | 10.00 | 9.33 |
Charts reference Space Occupied by Disconnect Drawing.
Allen Bradley
Allen Bradley 1494U Disconnect Switches
Fits Enclosure Depth | Alan Bradley | Amp | Space Occupied | When K=8.62 |
When K=11.62 |
||||
---|---|---|---|---|---|---|---|---|---|
8 | 12 | Type Number | Rating | Fuse Clip | Fuse Class | L | M | P | P |
• | • | DS30 | 30A | No Fuse | — | 3.88 | 6.62 | 6.75 | 9.75 |
• | • | DS30 | 30A | 30A-250V | H,K,R | 5.25 | 6.62 | 6.75 | 9.75 |
• | • | DS30 | 30A | 30A-600V | H,K,R | 8.00 | 6.62 | 6.75 | 9.75 |
• | • | DS30 | 30A | 30A-600V | J | 5.25 | 6.62 | 6.75 | 9.75 |
• | • | DS30 | 30A | 60A-250V | H,K | 6.00 | 6.62 | 6.75 | 9.75 |
• | • | DS30 | 30A | 60A-600V | H,K | 8.50 | 6.62 | 6.75 | 9.75 |
• | • | DS30 | 30A | 60A-600V | J | 5.38 | 6.62 | 6.75 | 9.75 |
• | • | DS60 | 60A | No Fuse | — | 3.88 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 60A-250V | H,K,R | 6.00 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 60A-600V | H,K,R | 8.50 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 60A-600V | J | 5.38 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 30A-600V | H,K,R | 8.00 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 100A-250V | H,K | 8.50 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 100A-600V | H,K | 10.50 | 6.62 | 6.62 | 9.62 |
• | • | DS60 | 60A | 100A-600V | J | 7.25 | 6.62 | 6.62 | 9.62 |
• | • | DS100¹ | 100A | No Fuse | — | 3.88 | 6.62 | 6.44 | 9.62 |
• | • | DS100¹ | 100A | 100A-250V | H,K,R | 8.12 | 6.62 | 6.44 | 9.62 |
• | • | DS100¹ | 100A | 100A-600V | H,K,R | 10.12 | 6.62 | 6.44 | 9.62 |
• | • | DS100¹ | 100A | 100A-600V | J | 6.88 | 6.62 | 6.44 | 9.62 |
• | • | DS100¹ | 100A | 60A-600V | H,K,R | 10.12 | 6.62 | 6.44 | 9.62 |
• | • | DS100¹ | 100A | 60A-600V | J | 8.88 | 6.62 | 6.44 | 9.62 |
• | DS200¹ | 200A | No Fuse | — | 4.75 | 7.88 | — | 8.12 | |
• | DS200¹ | 200A | 200A-250V | H,K,R | 10.88 | 7.88 | — | 8.12 | |
• | DS200¹ | 200A | 200A-600V | H,K,R | 13.38 | 7.88 | — | 8.12 | |
• | DS200¹ | 200A | 200A-600V | J | 9.50 | 7.88 | — | 8.12 | |
• | DS200¹ | 200A | 100A-600V | H,K,R | 12.00 | 7.88 | — | 8.12 | |
• | DS200¹ | 200A | 100A-600V | J | 8.75 | 7.88 | — | 8.12 |
1 Series B
2 "M" dimension does not allow for auxiliary switches. Allen Bradley 1494U Circuit Breakers
Fits Enclosure Depth | Allen Bradley Type No. |
Amp Rating | Fuse Type | Space Occupied |
When K=8.62 |
When K=11.62 |
||
---|---|---|---|---|---|---|---|---|
8 | 12 | L | M | P | P | |||
• | • | M40 | 15A to 150A | C-H Westinghouse Circuit Breakers EHD,FD,FDB,FDC,HFD,HMCP |
5.00 | 4.50¹ | 8.12 | |
11.12 | ||||||||
• | M50 | 70A to 250A | C-H Westinghouse Circuit Breakers JD,JDB,JDC,HJD,HMCP |
9.75 | 4.75¹ | — | ||
10.62 | ||||||||
• | M60 | 100A to 400A | C-H Westinghouse Circuit BreakersKD,KDB,DK,HKD,HMCP | 9.69 | 6.12¹ | — | ||
10.50 |
1 "M" dimension does not allow for auxiliary switches.
Charts reference Space Occupied by Disconnect Drawing.
Cutler Hammer
Cutler Hammer C361 Disconnect Switches
Fits Enclosure Depth | Cutler Hammer | Amp | Space Occupied | When K=8.62 |
When K=11.62 |
||||
---|---|---|---|---|---|---|---|---|---|
8 | 12 | Type Number | Rating | Fuse Clip | Fuse Class | L | M | P | P |
• | • | C361NC | 30A | No Fuse | — | 5.75 | 7.43 | 7.31 | 10.31 |
• | • | C361SC21 | 30A | 30A-250V | H, K, R | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361SC61 | 30A | 60A-250V | H, K, R | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361SC61 | 30A | 30A-600V | H, J, K, R | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361ND | 60A | No Fuse | — | 5.75 | 7.43 | 7.31 | 10.31 |
• | • | C361SD22 | 60A | 60A-250V | H, K, R | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361SD22 | 60A | 30A-600V | J | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361SD62 | 60A | 30A-600V | H, K, R | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361SD62 | 60A | 60A-600V | J | 8.38 | 7.43 | 7.31 | 10.31 |
• | • | C361NE | 100A | No Fuse | — | 5.56 | 8.95 | 7.47 | 9.91 |
• | • | C361SE263 | 100A | 100A-250V | H, K, R | 10.31 | 8.95 | 7.47 | 9.91 |
• | • | C361SE263 | 100A | 100A-600V | H, K, R | 10.31 | 8.95 | 7.47 | 9.91 |
• | • | C361SE263 | 100A | 100A-600V | J | 10.31 | 8.95 | 7.47 | 9.91 |
¹ , ² | ² | C361NF | 200A | No Fuse | — | 13.06 | 10.00 | 4.94 | 7.94 |
¹ , ² | ² | C361SF264 | 200A | 200A-250V | H, K, R | 13.06 | 10.00 | 4.94 | 7.94 |
¹ , ² | ² | C361SF264 | 200A | 200A-600V | H, J, K, R | 13.06 | 10.00 | 4.94 | 7.94 |
¹ Wire bend space "P" does not allow the use of maximum cable size in 8" deep enclosures.
² 200A switch should be installed in enclosures with an "A" dimension of 30" or greater.
Cutler Hammer C371 Circuit Breaker Operators (C-H Westinghouse Circuit Breakers)
Fits Enclosure Depth | Allen Bradley Type No. | Amp | Space Occupied | When K=8.62 | When K=11.62 | |||
---|---|---|---|---|---|---|---|---|
8 | 12 | Rating | Fuse Type | L | M | P | P | |
• | • | C371E | 150A | F Frame EHD,FDB,FD,HFD,FDC | 6.00 | 5.50 | 8.44 | 11.44 |
• | • | C371E | 150A | F Frame HMCP | 6.00 | 5.50 | 8.44 | 11.44 |
• | C371F | 250A | J Frame JDB,JD,HJD,JDC | 8.94 | 8.00 | — | 11.25 | |
• | C371F | 250A | J Frame HMCP | 10.94 | 8.00 | — | 11.25 | |
• | C371F | 400A | K Frame DK,KDB,KD,HKD | 9.75 | 8.00 | — | 10.75 | |
• | C371F | 400A | K Frame HMCP | 9.75 | 8.00 | — | 10.75 | |
• | C371G | 600A | L Frame LD,HLD,LDC | 8.44 | 11.88 | — | 9.18 | |
• | C371G | 600A | L Frame HMCP | 8.44 | 11.88 | — | 9.18 |
Charts reference Space Occupied by Disconnect Drawing.
Cutler Hammer Flex-Shaft™ Operator Mechanisms (C-H Westinghouse Circuit Breakers)
Fits Enclosure Depth | Complete Operator | Breaker Height | Breaker Width | |||
---|---|---|---|---|---|---|
8 | 12 | Mechansim | Amp Rating | Fuse Type | "X" | "Y" |
• | • | F1S03 | 150A | F Frame EHD,FDB,FD,HFD,FDC | 6.00 | 4.12 |
• | • | F1S03 | 150A | F Frame HMCP | 6.00 | 4.12 |
• | • | F2S03 | 250A | J Frame JDB,JD,HJD,JDC | 10.00 | 4.12 |
• | • | F2S03 | 250A | J Frame HMCP | 10.00 | 4.12 |
• | • | F3S03 | 400A | K Frame DK,KDB,KD,HKD | 10.12 | 5.50 |
• | • | F3S03 | 400A | K Frame HMCP | 12.45 | 5.50 |
• | F4S04 | 600A | L Frame LD,HLD,LDC | 10.75 | 8.25 | |
• | F7S04 | 800A | M Frame MD,MDS | 16.00 | 8.25 | |
• | F5S04 | 1200A | N Frame ND,HND,NDC | 16.00 | 8.25 | |
• | F6S04 | 2500A | R Frame RD,CRD, RDC | 16.00 | 15.50 |
Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism.
The last digit of the part number denotes the shaft length (F1S03=3' length).
- F,J,K frame Flex-Shafts™ available in 3' to 10' lengths.
- L,N,R frame Flex-Shafts™ available in 4' to 6' lengths.
Space Occupied By Disconnect
1. Flex-Shaft™ System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft™.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing.
General Electric
General Electric Type STDA Disconnect Switches
Fits Enclosure Depth | General Electric Mechanism For Switch |
Amp Rating |
Space Occupied | When K=8.62 |
When K=11.62 |
||||
---|---|---|---|---|---|---|---|---|---|
8 | 12 | Fuse Clip | Fuse Class | L | M | P | P | ||
• | • | TDOM1A | 30A | No Fuse | — | 7.75¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1A | 30A | 30A-250V | H, R | 7.75¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 30A | 30A-600V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 30A | 60A-250V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 30A | 60A-600V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1A | 60A | No Fuse | — | 7.75¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 60A | 60A-250V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 60A | 60A-600V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 60A | 100A-250V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 60A | 100A-600V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1A | 100A | No Fuse | — | 7.75¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 100A | 100A-250V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 100A | 100A-600V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 100A | 200A-250V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM1B | 100A | 200A-600V | H, R | 12.38¹ | 5.25 | 9.12 | 12.12 |
• | • | TDOM2 | 200A | No Fuse | — | 7.00 | 9.12 | 6.50 | 9.50 |
• | • | TDOM2 | 200A | 200A-250V | H, R | 15.38 | 9.12 | 6.50 | 9.50 |
• | • | TDOM2 | 200A | 200A-600V | H, R | 15.38 | 9.12 | 6.50 | 9.50 |
¹ Applies to 8" deep enclosures, and is 0.875" less in 12" deep enclosures.
General Electric Type STDA Circuit Breaker Operators
Fits Enclosure Depth | General Electric Mechanism For Switch |
Amp Rating | Space Occupied | When K=8.62 |
When K=11.62 |
|||
---|---|---|---|---|---|---|---|---|
8 | 12 | Fuse Type | L | M | P | P | ||
• | • | SDOM1A | 150A | TEB, TED, THED | 7.75¹ | 5.25 | 9.06 | 12.06 |
• | • | SDOM1A | 150A | TEC | 7.75¹ | 5.25 | 9.06 | 12.06 |
• | • | TDOM1B | 150A | TB1 | 12.38¹ | 5.25 | 9.06 | 12.06 |
• | • | TDOM1B | 150A | TEC, TECL | 12.38¹ | 5.25 | 9.06 | 12.06 |
• | • | TDOM1C | 150A | TEL | 7.75¹ | 5.25 | 9.06 | 12.06 |
• | • | TDOM1D | 150A | THLC1 | 7.75¹ | 5.25 | 6.62 | 9.62 |
• | • | TDOM3 | 225A | TFJ | 10.38 | 5.75 | 7.62 | 10.62 |
• | • | TDOM3 | 225A | TFK, THFK, TFL | 10.38 | 5.75 | 7.62 | 10.62 |
• | • | TDOM4 | 400A | TJJ, TJK4, THJK4, TJL4V | 8.25 | 9.38 | 6.69 | 9.69 |
• | • | TDOM4 | 600A | TJK6, THJK6, TJ4V, TJL4V | 8.25 | 9.38 | 6.69 | 9.69 |
• | • | TDOM5 | 400A | TB4, TJH6S | 14.25 | 9.38 | 6.69 | 9.69 |
• | • | TDOM6 | 225A | TLB2, THLC2 | 11.75 | 9.38 | 6.12 | 9.12 |
• | • | TDOM6 | 400A | TLB4, THLC4 | 11.75 | 9.38 | 4.75 | 7.75 |
• | • | SDOM1A | 150A | SPECTRA SE150 | 7.75¹ | 5.25 | 9.06 | 12.06 |
• | • | SDOM3 | 250A | SPECTRA SF250 | 10.38 | 5.75 | 7.06 | 10.06 |
• | SDOM4 | 600A | SPECTRA SG600 | 10.00 | 7.00 | — | 7.93 |
¹ Applies to 8" deep enclosures, and is 0.875" less in 12" deep enclosures.
Charts reference Space Occupied by Disconnect Drawing.
General Electric Circuit Breakers (Spectra-Flex™ Cable Operators)
Fits Enclosure Depth | Circuit Breaker Height | Circuit Breaker Width | |||
---|---|---|---|---|---|
C=8 | C=12 | Frame Size | Max Amp Rating | X | Y |
• | • | E150 | 150A | 6.31 | 4.12 |
• | • | SE150 | 150A | 6.31 | 4.12 |
• | SF250 | 250A | 10.12 | 4.12 | |
• | SG600 | 600A | 10.09 | 5.50 | |
• | SK1200 | 1200A | 15.50 | 8.25 |
Frame Size | Breaker Mechanism | Flange Mounting Handle¹ | Operating Cable² |
---|---|---|---|
E150 | SCOM1A | SCH1 | SC3L |
SE150/SF250 | SCOM1EF | SCH1 | SC3L |
SG600 | SCOM1G | SCH1 | SC3L |
SK1200 | SCOM1K | SCH2K | SC3H |
- GE Spectra-Flex™ Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism.
- See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
- Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft™.
- Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left
Charts reference Space Occupied by Disconnect Drawing.
Siemens I-T-E
I-T-E - Disconnect Switches (Max-Flex™ Operators)
Fits Enclosure Depth | Amp Rating |
Disconnect Height "X" |
Disconnect Width "Y" |
||||
---|---|---|---|---|---|---|---|
C=8 | C=12 | Switch | Fuse Clip | Fuse Class | |||
• | • | MCS603R | 30A | No Fuse | — | 5.52 | 6.13 |
• | • | MCS603R | 30A | 30A-250V | H,K,R | 8.11 | 6.13 |
• | • | MCS603R | 30A | 30A-600V | H,K,R | 10.11 | 6.13 |
• | • | MCS603R | 30A | 30A-600V | J | 8.48 | 6.13 |
• | • | MCS606R | 60A | No Fuse | — | 5.52 | 6.13 |
• | • | MCS606R | 60A | 60A-250V | H,K,R | 7.86 | 6.13 |
• | • | MCS606R | 60A | 60A-600V | H,K,R | 10.38 | 6.13 |
• | • | MCS606R | 60A | 60A-600V | J | 8.36 | 6.13 |
• | • | MCS610R | 100A | No Fuse | — | 7.59 | 7.38 |
• | • | MCS610R | 100A | 100A-250V | H,K,R | 11.85 | 7.38 |
• | • | MCS610R | 100A | 100A-600V | H,K,R | 13.85 | 7.38 |
• | • | MCS610R | 100A | 100A-600V | J | 10.60 | 7.38 |
• | • | MCS620R | 200A | No Fuse | — | 9.00 | 9.17 |
• | • | MCS620R | 200A | 200A-250V | H,K,R | 14.70 | 9.17 |
• | • | MCS620R | 200A | 200A-600V | H,K,R | 17.20 | 9.17 |
• | • | MCS620R | 200A | 200A-600V | J | 13.32 | 9.17 |
Siemens I-T-E Max-Flex™ Operators (Circuit Breakers)
Complete Operator Mechansim | Breaker Frame Size |
Circuit Breaker Type | Circuit Breaker Height "X" |
Circuit Breaker Width "Y" |
|
---|---|---|---|---|---|
Amp Rating | |||||
FHOE036 | 125A | ED | ED2,ED4,ED6,HED4,HED6, | 6.34 | 3.00 |
FHOE036 | 125A | CED | CED6 | 9.58 | 3.00 |
FHOF036 | 250A | FD | FXD6-A,FD6-A,HFD6,FXD6-ETJ,HHFD6, HHFXD6 | 9.50 | 4.50 |
FHOF036 | 250A | CFD | CFD6,CFD6-ETI | 14.25 | 4.50 |
FHOJ036 | 400A, 600A | JD, LD | JXD2,LXD6,JD6,LD6,HJD6,HLD6,HHJD6,HHLD6, HHJXD6,HHLXD6,JXD6-ETI,LXD6-ETI | 11.00 | 7.50 |
FHOJ036 | 400A, 600A | CJD,CLD | CJD6,CLD6,CJD6-ETI,CLD6-ETI | 17.86 | 7.50 |
FHOLMO36 | 800A | LMD | LMD6,LMXD6,HLMD6,HLMDX6,LMXD6-ETI | 16.00 | 9.00 |
- 48" cables are offered for ED,FD,JD/LD operators
Space Occupied By Disconnect
1. I-T-E Max-Flex™ System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex™ cables.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left.
- Charts reference Space Occupied by Disconnect Drawing.
Square D
Square D Class 9422 Disconnect Switches
Fits Enclosure Depth | Amp Rating |
Space Occupied | When K=8.62 P |
When K=11.62 P |
|||||
---|---|---|---|---|---|---|---|---|---|
8 | 12 | Square D Type Number | Fuse Clip | Fuse Class | L | M | |||
• | • | TCN-30 | 30A | No Fuse | — | 3.80 | 6.84 | 7.56 | 10.56 |
• | • | TCF-30 | 30A | 30A-250V | H, K, R | 5.53 | 6.84 | 7.56 | 10.56 |
• | • | TCF-33 | 30A | 30A-600V | H, K, R | 8.15 | 6.84 | 7.56 | 10.56 |
• | • | TCF-33 | 30A | 60A-250V | H, K, R | 6.15 | 6.84 | 7.56 | 10.56 |
• | • | TCF-33 | 30A | 30A-600V | J | 5.53 | 6.84 | 7.56 | 10.56 |
• | • | TDN-60 | 60A | No Fuse | — | 3.80 | 6.84 | 7.56 | 10.56 |
• | • | TDF-60 | 60A | 30A-600V | H, K, R | 8.15 | 6.84 | 7.56 | 10.56 |
• | • | TDF-60 | 60A | 60A-250V | H, K, R | 6.15 | 6.84 | 7.56 | 10.56 |
• | • | TDF-63 | 60A | 60A-600V | H, K, R | 8.65 | 6.84 | 7.56 | 10.56 |
• | • | TDF-63 | 60A | 60A-600V | J | 5.53 | 6.84 | 7.56 | 10.56 |
• | TEN-10 | 100A | No Fuse | — | 3.80 | 6.84 | 7.44 | 10.44 | |
• | TEF-10 | 100A | 100A-250V | H, K, R | 8.25 | 6.84 | 7.44 | 10.44 | |
• | TEF-10 | 100A | 100A-600V | H, K, R | 10.25 | 6.84 | 7.44 | 10.44 | |
• | TEF-10 | 100A | 100A-600V | J | 7.05 | 6.84 | 7.44 | 10.44 | |
• | • | TC-1 | 30A | No Fuse | — | 5.75 | 6.00 | 6.62 | 9.62 |
• | • | TC-2 | 30A | 30A-250V | H, K, R | 5.75 | 6.00 | 6.62 | 9.62 |
• | • | TC-3 | 30A | 30A-600V | H, K, R | 7.75 | 6.00 | 6.62 | 9.62 |
• | • | TC-3 | 30A | 60A-250V | H, K, R | 5.88 | 6.00 | 6.62 | 9.62 |
• | • | TC-3 | 30A | 30A-600V | J | 5.75 | 6.00 | 6.62 | 9.62 |
• | • | TD-1 | 60A | No Fuse | — | 6.38 | 6.62 | 7.50 | 10.50 |
• | • | TD-2 | 60A | 30A-600V | H, K, R | 8.50 | 6.62 | 7.50 | 10.50 |
• | • | TD-2 | 60A | 60A-250V | H, K, R | 6.50 | 6.62 | 7.50 | 10.50 |
• | • | TD-3 | 60A | 60A-600V | H, K, R | 9.00 | 6.62 | 7.50 | 10.50 |
• | • | TD-3 | 60A | 60A-600V | J | 6.38 | 6.62 | 7.50 | 10.50 |
• | TE-1 | 100A | No Fuse | — | 4.75 | 8.38 | — | 10.25 | |
• | TE-2 | 100A | 100A-250V | H, K, R | 7.50 | 8.38 | — | 10.25 | |
• | TE-2 | 100A | 100A-600V | H, K, R | 9.50 | 8.38 | — | 10.25 | |
• | TE-2 | 100A | 100A-600V | J | 6.25 | 8.38 | — | 10.25 | |
• | TE-3 | 100A | 200A-600V | J | 13.75 | 8.38 | — | 10.25 | |
• | TF-1 | 200A | No Fuse | — | 5.50 | 11.62 | — | 8.88 | |
• | TF-2 | 200A | 200A-250V | H, K, R | 11.50 | 11.62 | — | 8.88 | |
• | TF-2 | 200A | 200A-600V | H, K, R | 14.00 | 11.62 | — | 8.88 | |
• | TF-2 | 200A | 200A-600V | J | 10.12 | 11.62 | — | 8.88 | |
• | TF-3 | 200A | 400A-600V | J | 14.50 | 11.62 | — | 8.88 |
Square D Class 9422 Variable Depth Operators (Circuit Breakers)
Fits Enclosure Depth | General Electric Mechanism For Switch |
Amp Ratingthtd> |
Space Occupied | When K=8.62 P |
When K=11.62 P |
|||
---|---|---|---|---|---|---|---|---|
8 | 12 | Frame Size | L | M | ||||
• | • | RG-1 | 75A | GJL | 3.53 | 3.74 | 7.47 | 10.47 |
• | • | RG-1 | 100A | GJL | 3.53 | 3.74 | 7.47 | 10.47 |
• | • | RN-1 | 100A | FAL,FHL | 5.12 | 5.25 | 7.62 | 10.62 |
• | • | RP-1 | 250A | KAL,KHL | 7.12 | 5.62 | 8.38 | 11.38 |
• | RR-1 | 400A | LAL, LHL, Q4L | 7.62 | 8.75 | — | 7.00 |
Charts reference Space Occupied by Disconnect Drawing.
Square D Class 9422 Disconnect Switches (Cable Mechanism 9422-CFT30 and 9422A-1 Handle Mechanism)
Fits Enclosure Depth | Square D Type Number |
Amp Rating |
Disconnect Height "X" |
Disconnect Width "Y" |
|||
---|---|---|---|---|---|---|---|
C=8 | C=12 | Fuse Clip | Fuse Class | ||||
• | • | TCN-30 | 30A | No Fuse | — | 5.90 | 6.20 |
• | • | TCF-30 | 30A | 30A-250V | H, K, R | 7.50 | 6.20 |
• | • | TCF-33 | 30A | 30A-600V | H, K, R | 10.15 | 6.20 |
• | • | TCF-33 | 30A | 60A-250V | H, K, R | 8.15 | 6.20 |
• | • | TCF-33 | 30A | 30A-600V | J | 7.50 | 6.20 |
• | • | TDN-60 | 60A | No Fuse | — | 5.90 | 6.20 |
• | • | TDF-60 | 60A | 30A-600V | H, K, R | 10.15 | 6.20 |
• | • | TDF-60 | 60A | 60A-250V | H, K, R | 8.15 | 6.20 |
• | • | TDF-63 | 60A | 60A-600V | H, K, R | 10.65 | 6.20 |
• | • | TDF-63 | 60A | 60A-600V | J | 7.50 | 6.20 |
• | TEN-10 | 100A | No Fuse | — | 5.90 | 6.20 | |
• | TEF-10 | 100A | 100A-250V | H, K, R | 10.35 | 6.20 | |
• | TEF-10 | 100A | 100A-600V | H, K, R | 12.35 | 6.20 | |
• | TEF-10 | 100A | 100A-600V | J | 10.35 | 6.20 |
Square D Class 9422 Cable Mechanism (Circuit Breakers)
Fits Enclosure Depth | Amp | Circuit Breaker | Circuit Breaker | |||
---|---|---|---|---|---|---|
C=8 | C=12 | Cable Type Switch | Rating | Frame Type | Height "X" | Width "Y" |
• | • | 9422 CGJ30 | 75A | GJL | 4.75 | 3.50 |
• | • | 9422 CEJ30 | 100A | GJL | 4.75 | 3.50 |
• | • | 9422 CFA30 | 100A | FAL,FHL | 6.00 | 4.50 |
• | • | 9422 CKA30 | 250A | KAL,KHL | 8.00 | 4.50 |
• | 9422 CLA30 | 400A | LAL,LHL,Q4L | 11.00 | 6.00 |
Cable operators are offered in 3’, 5’, and 10’ lengths. Last 2 digits of part numbers above (30) are for 3’ cables
Space Occupied By Disconnect Switch
1. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors.
3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
Charts reference Space Occupied by Disconnect Drawing.