ABB Controls Disconnect Switches (Flange Mounted Operators)
Fits Enclosure Height | ABB Switch Number |
Amp | Space Occupied |
When A=60.13 P |
When A=72.13 P |
|||||
60.13 | 72.13 | Rating | Fuse Clip | Fuse Class | L | M | N | |||
• | • | OETL-NF30-F | 30A | No Fuse | — | 4.45 | 3.91 | 0.25 | 9.53 | 15.53 |
• | • | OETL-NF60-F | 60A | No Fuse | — | 4.86 | 3.91 | 0.25 | 9.34 | 15.34 |
• | • | OETL-NF100-F | 100A | No Fuse | — | 4.86 | 4.91 | 0.25 | 8.78 | 14.78 |
• | • | OETL-NF175-F | 175A | No Fuse | — | 7.30 | 6.62 | 0.25 | 6.53 | 12.53 |
• | • | OETL-NF200-F | 200A | No Fuse | — | 7.36 | 7.41 | 0.25 | 6.53 | 12.53 |
• | • | OESA-F30J6-F | 30A | 30A-600V | J | 4.28 | 6.70 | 0.25 | 7.85 | 13.86 |
• | • | OESA-F60J6-F | 60A | 60A-600V | J | 4.28 | 6.39 | 0.25 | 7.85 | 13.86 |
• | • | OESA-F100J6-F | 100A | 100A-600V | J¹ | 6.54 | 7.78 | 0.25 | 7.42 | 13.42 |
200A² |
² 200 A available by using non-fusible 200A switch and a trailing fuse block. (consult ABB) ABB Controls Circuit Breaker (Flange Mounted Operators)
Fits Enclosure Height | ISOMAX Circuit Breaker |
Amp Rating |
Operating Mechanism |
Frame Type |
Space Occupied | When A=60.13 P |
When A=72.13 P |
|||
60.13 | 72.13 | L | M | N | ||||||
• | • | S1N100TL | 100A | K2FHD-M | S1 | 5.30 | 4.60 | 0.63 | 8.33 | 14.33 |
• | • | S3N150TW | 150A | K3FHD-M | S3 | 6.67 | 5.02 | 0.63 | 7.73 | 13.73 |
• | • | S3N225TW | 225A | K3FHD-M | S3 | 6.67 | 5.02 | 0.63 | 7.73 | 13.73 |
• | • | S4N250BW | 250A | K4FHD-M | S4 | 8.45 | 5.02 | 0.63 | 6.20 | 12.20 |
• | • | S5N400TW | 400A | K5FHD-M | S5 | 8.45 | 6.40 | 0.63 | 6.20 | 12.20 |
• | • | S6N600TW | 600A | K6FHD-M | S6 | 8.33 | 10.00 | 0.63 | 5.53 | 11.53 |
• | • | S6N800TW | 800A | K6FHD-M | S6 | 8.33 | 10.00 | 0.63 | 5.53 | 11.53 |
"K" = 13.88 when "A" = 72.13 Charts reference Space Occupied by Disconnect Drawing.
Allen Bradley
Allen Bradley 1494F Disconnect SwitchesFits Enclosure Height | Allen Bradley Switch Number |
Amp Rating |
Space Occupied M¹ |
When A=60.13 P |
When A=72.13 P |
|||||
60.13 | 72.13 | Fuse Clip | Fuse Class | L | N | |||||
• | • | N30 | 30A | No Fuse | — | 4.62 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | NF30 | 30A | 30A-250V | H, K, R | 6.50 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | NF30 | 30A | 60A-250V | H, K, R | 7.25 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | NF30 | 30A | 30A-600V | H, K, R | 9.25 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | NF30 | 30A | 60A-600V | H, K, R | 9.75 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | NF30 | 30A | 30A-600V | J | 6.50 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | NF30 | 30A | 60A-600V | J | 6.62 | 6.50 | 0.63 | 5.31 | 11.31 |
• | • | N60 | 60A | No Fuse | — | 4.62 | 6.50 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 30A-600V | H, K, R | 10.38 | 6.50 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 60A-250V | H, K, R | 8.38 | 6.50 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 100A-250V | H, K, R | 10.88 | 6.50 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 60A-600V | H, K, R | 10.88 | 6.50 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 100A-600V | H, K, R | 12.88 | 6.62 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 60A-600V | J | 7.75 | 6.50 | 0.63 | 4.62 | 10.62 |
• | • | NF60 | 60A | 100A-600V | J | 9.75 | 6.50 | 0.63 | 4.62 | 10.62 |
• | N100 | 100A | No Fuse | — | 4.62 | 7.25 | 0.63 | — | 8.75 | |
• | NF100 | 100A | 100A-250V | H, K, R | 11.38 | 7.38 | 0.63 | — | 8.75 | |
• | NF100 | 100A | 200A-250V | H, K, R | 12.25 | 7.62 | 0.63 | — | 8.75 | |
• | NF100 | 100A | 100A-600V | H, K, R | 13.38 | 7.50 | 0.63 | — | 8.75 | |
• | NF100 | 100A | 200A-600V | H, K, R | 14.75 | 7.75 | 0.63 | — | 8.75 | |
• | NF100 | 100A | 100A-600V | J | 10.12 | 7.38 | 0.63 | — | 8.75 | |
• | NF100 | 100A | 200A-600V | J | 10.88 | 7.50 | 0.63 | — | 8.75 | |
• | N200 | 200A | No Fuse | — | 7.12 | 10.38 | 0.56 | — | 7.13 | |
• | NF200 | 200A | 200A-250V | H, K, R | 15.00 | 10.38 | 0.56 | — | 7.13 | |
• | NF200 | 200A | 400A-250V | H, K, R | 16.56 | 10.75 | 0.56 | — | 7.13 | |
• | NF200 | 200A | 200A-600V | H, K, R | 17.56 | 10.38 | 0.56 | — | 7.13 | |
• | NF200 | 200A | 400A-600V | H, K, R | 19.56 | 11.00 | 0.56 | — | 7.13 | |
• | NF200 | 200A | 200A-600V | J | 13.69 | 10.38 | 0.56 | — | 7.13 | |
• | NF200 | 200A | 400A-600V | J | 15.00 | 10.62 | 0.56 | — | 7.13 |
¹"M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required.
Allen Bradley 1494D Operators (Circuit Breakers)
Fits Enclosure Height | Alan Bradley Type Number |
Amp Rating |
Circuit Breker Type | Space Occupied |
When A=60.13 P |
When A=72.13 P |
|||
60.13 | 72.13 | L | M¹ | N | |||||
• | • | N4/N40 | 150A | C-H Westinghouse EHD,FD,FDB,FDC,HFD,HMCP |
5.81 | 4.56 | 0.63 | 5.25 | 11.25 |
• | • | N5/N55 | 225A | General Electric TFK, THFK, TFC |
8.81 | 4.75 | 0.63 | 4.44 | 10.44 |
• | • | N5/N50 | 250A | C-H Westinghouse JD,JDB,JDC,HJD,HMCP |
8.81 | 4.75 | 0.63 | 4.44 | 10.44 |
• | N5/N60 | 400A | C-H Westinghouse KD,KDB,DK,HKD,HMCP |
8.81 | 5.88 | 0.63 | — | 10.50 |
1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required.
"K" = 5.88 when "A" = 60.13
"K" = 11.88 when "A" = 72.13 (except 200A switches)
"K" = 10.56 when "A" = 72.13 (200A switches only).
Allen Bradley 1494U Operators (Disconnect Switches)
Fits Enclosure Height | Alan Bradley Switch Number |
Amp | Space Occupied |
When A=60.13 P |
When A=72.13 P |
|||||
60.13 | 72.13 | Rating | Fuse Clip | Fuse Class | L | M² | N | |||
• | • | DS30 | 30A | No Fuse | — | 3.88 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS30 | 30A | 30A-250V | H,K,R | 5.25 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS30 | 30A | 30A-600V | H,K,R | 8.00 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS30 | 30A | 30A-600V | J | 5.25 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS30 | 30A | 60A-250V | H,K | 6.00 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS30 | 30A | 60A-600V | H,K | 8.50 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS30 | 30A | 60A-600V | J | 5.38 | 6.75 | 1.06 | 6.00 | 12.00 |
• | • | DS60 | 60A | No Fuse | — | 3.88 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 60A-250V | H,K,R | 6.00 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 60A-600V | H,K,R | 8.50 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 60A-600V | J | 5.38 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 30A-600V | H,K,R | 8.00 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 100A-250V | H,K | 8.50 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 100A-600V | H,K | 10.50 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS60 | 60A | 100A-600V | J | 7.25 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS100¹ | 100A | No Fuse | — | 3.88 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS100¹ | 100A | 100A-250V | H,K,R | 8.12 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS100¹ | 100A | 100A-600V | H,K,R | 10.12 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS100¹ | 100A | 100A-600V | J | 6.80 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS100¹ | 100A | 60A-600V | H,K,R | 10.12 | 6.75 | 1.06 | 5.81 | 11.81 |
• | • | DS100¹ | 100A | 60A-600V | J | 8.88 | 6.75 | 1.06 | 5.81 | 11.81 |
• | DS2001 | 200A | No Fuse | — | 4.75 | 8.00 | 1.06 | — | 10.34 | |
• | DS2001 | 200A | 200A-250V | H,K,R | 10.88 | 8.00 | 1.06 | — | 10.34 | |
• | DS2001 | 200A | 200A-600V | H,K,R | 13.88 | 8.00 | 1.06 | — | 10.34 | |
• | DS2001 | 200A | 200A-600V | J | 9.50 | 8.00 | 1.06 | — | 10.34 | |
• | DS2001 | 200A | 100A-600V | H,K,R | 12.00 | 8.00 | 1.06 | — | 10.34 | |
• | DS2001 | 200A | 100A-600V | J | 8.75 | 8.00 | 1.06 | — | 10.34 |
1 Series B
2 "M" dimension does not allow for auxiliary switches
Allen Bradley 1494U Operators (Circuit Breakers)
Fits Enclosure Height | Alan Bradley Type Number |
Amp | Space Occupied |
When A=60.13 P |
When A=72.13 P |
||||
60.13 | 72.13 | Rating | Circuit Breker Type | L | M1 | N | |||
• | • | M40 | 15A-150A | C-H Westinghouse EHD,FD,FDB,FDC,HFD,HMCP |
5.00 | 4.62 | 1.06 | 7.25 | 13.25 |
• | • | M50 | 70A-250A | C-H Westinghouse JD,JDB,JDC,HJD,HMCP |
9.75 | 4.88 | 1.06 | 6.81 | 12.81 |
• | M60 | 100A-400A | C-H Westinghouse KD,KDB,DK,HKD,HMCP |
9.69 | 6.25 | 1.06 | — | 12.62 |
1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required.
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13
Cutler Hammer
Cutler Hammer C361 Disconnect Switches
Fits Enclosure Height | Cutler Hammer Type Number |
Amp | Space Occupied |
When A=60.13 P |
When A=72.13 P |
|||||
60.13 | 72.13 | Rating | Fuse Clip | Fuse Class | L | M | N | |||
• | • | C361NC | 30A | No Fuse | — | 5.75 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SC21 | 30A | 30A-250V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SC61 | 30A | 60A-250V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SC61 | 30A | 30A-600V | H, J, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361ND | 60A | No Fuse | — | 5.75 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SD22 | 60A | 60A-250V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SD22 | 60A | 30A-600V | J | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SD62 | 60A | 60A-600V | H, K, R | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361SD62 | 60A | 60A-600V | J | 8.38 | 7.55 | 0.63 | 6.50 | 12.50 |
• | • | C361NE | 100A | No Fuse | — | 5.56 | 9.07 | 0.63 | 6.06 | 12.06 |
• | • | C361SE263 | 100A | 100A-250V | H, K, R | 10.31 | 9.07 | 0.63 | 6.06 | 12.06 |
• | • | C361SE263 | 100A | 100A-600V | H, K, R | 10.31 | 9.07 | 0.63 | 6.06 | 12.06 |
• | • | C361SE263 | 100A | 100A-600V | J | 10.31 | 9.07 | 0.63 | 6.06 | 12.06 |
• | • | C361NF | 200A | No Fuse | — | 13.06 | 10.12 | 0.63 | 4.06 | 10.12 |
• | • | C361SF264 | 200A | 200A-250V | H, K, R | 13.06 | 10.12 | 0.63 | 4.06 | 10.12 |
• | • | C361SF264 | 200A | 200A-600V | H, K, R, J | 13.06 | 10.12 | 0.63 | 4.06 | 10.12 |
Fits Enclosure Height | Cutler Hammer Mechanisms |
Amp | Space Occupied | When A=60.13 P |
When A=72.13 P |
||||
60.13 | 72.13 | Rating | Frame Type | L | M | N | |||
• | • | C371E | 150A | F Frame EHD,FDB,FD,HFD,FDC | 6.00 | 5.62 | 0.63 | 7.62 | 13.62 |
• | • | C371E | 150A | F Frame HMCP | 6.00 | 5.62 | 0.63 | 7.62 | 13.62 |
¹ | • | C371F | 250A | J Frame JDB,JD,HJD,JDC | 8.94 | 8.12 | 0.63 | 7.50 | 13.50 |
¹ | • | C371F | 250A | J Frame HMCP | 10.94 | 8.12 | 0.63 | 7.50 | 13.50 |
¹ | • | C371F | 400A | K Frame DK,KDB,KD,HKD | 9.75 | 8.12 | 0.63 | 7.00 | 13.00 |
¹ | • | C371F | 400A | K Frame HMCP | 9.75 | 8.12 | 0.63 | 7.00 | 13.00 |
² | C371G | 600A | L Frame LD,HLD,LDC | 8.44 | 12.00 | 0.63 | - | 11.38 | |
² | C371G | 600A | L Frame HMCP | 8.44 | 12.00 | 0.63 | - | 11.38 |
2Wire bend space "P" does not allow cable size larger than 300 MCM.
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing. Cutler Hammer Flex-Shaft™ Operator Mechanisms (C-H Westinghouse Circuit Breakers)
Complete Operator | Breaker Height "X" | Breaker Width "Y" | ||
Mechanisms | Amp Rating | Frame Type | (in inches) | (in inches) |
F1S03 | 150A | F Frame EHD,FDB,FD,HFD | 6.00 | 4.12 |
F1S03 | 150A | F Frame HCMP | 6.00 | 4.12 |
F2S03 | 250A | J Frame JDB,JD,HJD,JDC | 10.00 | 4.12 |
F2S03 | 250A | J Frame HCMP | 10.00 | 4.12 |
F3S03 | 400A | K Frame DK,KDB,KD,HKD | 10.12 | 5.50 |
F3S03 | 400A | K Frame HCMP | 12.45 | 5.50 |
F4S04 | 600A | L Frame LD,HLD,LDC | 10.75 | 8.25 |
F7S04 | 800A | M Frame MD,MDS | 16.00 | 8.25 |
F5S04 | 1200A | N Frame ND,HND,NDC | 16.00 | 8.25 |
F6S04 | 2500A | R Frame RD,CRD, RDC | 16.00 | 15.50 |
Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism.
The last digit of the part number denotes the shaft length (F1S03=3' length).
F,J,K frame Flex-Shafts™ available in 3' to 10' lengths.
L,N,R frame Flex-Shafts™ available in 4' to 6' lengths.
Space Occupied By Disconnect
1. Flex-Shaft™ System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors.
3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft™.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing
General ElectricGeneral Electric Type STDA Disconnect Switche Operators
Fits Enclosure Height | General Electric Switch Mechanisms |
Amp Rating |
Space Occupied M |
When A=60.13 P |
When A=72.13 P |
|||||
60.13 | 72.13 | Fuse Clip | Fuse Class | L | N | |||||
• | • | TDOM1A | 30A | No Fuse | - | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1A | 30A | 30A-250V | H, R | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 30A | 30A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 30A | 60A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 30A | 60A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1A | 60A | No Fuse | - | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 60A | 60A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 60A | 60A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 60A | 100A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 60A | 100A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1A | 100A | No Fuse | - | 6.88 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 100A | 100A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 100A | 100A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 100A | 200A-250V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM1B | 100A | 200A-600V | H, R | 11.5 | 5.38 | 0.63 | 8.38 | 14.38 |
• | • | TDOM2 | 200A | No Fuse | - | 7 | 9.25 | 0.63 | 5.69 | 11.69 |
• | • | TDOM2 | 200A | 200A-250V | H, R | 15.38 | 9.25 | 0.63 | 5.69 | 11.69 |
• | • | TDOM2 | 200A | 200A-600V | H, R | 15.38 | 9.25 | 0.63 | 5.69 | 11.69 |
Fits Enclosure Height | General Electric Circuit Breaker Mechanisms |
Amp Rating |
Frame Type | Space Occupied | When A=60.13 P |
When A=72.13 P |
|||
60.13 | 72.13 | L | M | N | |||||
• | • | TDOM1A | 150A | TEB, TED, THED | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
• | • | TDOM1A | 150A | TEC | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
• | • | TDOM1B | 150A | TB1 | 11.50 | 5.38 | 0.63 | 7.24 | 13.24 |
• | • | TDOM1B | 150A | TEC, TECL | 11.50 | 5.38 | 0.63 | 7.24 | 13.24 |
• | • | TDOM1C | 150A | TEL | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
• | • | TDOM1D | 150A | THLC1 | 6.88 | 5.38 | 0.63 | 5.87 | 11.87 |
• | • | TDOM3 | 225A | TFJ | 10.38 | 5.88 | 0.63 | 6.81 | 12.81 |
• | • | TDOM3 | 225A | TFK, THFK, TFL | 10.38 | 5.88 | 0.63 | 6.81 | 12.81 |
• | TDOM4 | 400A | TJJ, TJK4, THJK4, TJL4V | 8.25 | 9.50 | 0.63 | — | 11.91 | |
• | TDOM4 | 600A | TJK6, THJK6, TJ4V, TJL4V | 8.25 | 9.50 | 0.63 | — | 11.91 | |
• | TDOM5 | 400A | TB4, TJH6S | 14.25 | 9.50 | 0.63 | — | 11.91 | |
• | TDOM6 | 225A | TLB2, THLC2 | 11.75 | 9.50 | 0.63 | — | 11.35 | |
• | TDOM6 | 400A | TLB4, THLC4 | 11.75 | 9.50 | 0.63 | — | 9.97 | |
• | • | SDOM1A | 150A | SE150 | 6.88 | 5.38 | 0.63 | 7.24 | 13.24 |
• | • | SDOM3 | 250A | SPECTRA SF250 | 10.38 | 5.88 | 0.63 | 6.81 | 11.88 |
• | SDOM4 | 600A | SPECTRA SG600 | 10.00 | 7.12 | 0.63 | — | 9.18 |
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13 General Electric Circuit Breakers (Spectra-Flex™ Cable Operators)
Fits Enclosure Height | Circuit Breaker Height | Circuit Breaker Width | |||
60.13 | 72.13 | Frame Size | Max Amp Rating | "X" | "Y" |
• | • | E150 | 150A | 6.31 | 4.12 |
• | • | SE150 | 150A | 6.31 | 4.12 |
• | • | SF250 | 250A | 10.12 | 4.12 |
• | • | SG600 | 600A | 10.09 | 5.50 |
• | • | SK1200 | 1200A | 15.50 | 8.25 |
Note: All 2UD,2UDF,2UDCP series enclosures that are 24.00" deep require a 48" or longer operating cable
Frame Size | Breaker Mechanism | Flange Mounting Handle¹ | Operating Cable² |
E150 | SCOM1A | SCH1 | SC3L |
SE150/SF250 | SCOM1EF | SCH1 | SC3L |
SG600 | SCOM1G | SCH1 | SC3L |
SK1200 | SCOM1K | SCH2K | SC3H |
2Operating Cables are available 3' to 10' lengths. In the table above, the number "3" in the part number indicates a 3' cable.
Space Occupied By Disconnect
1. GE Spectra-Flex™ Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref "P") needed for line side conductors.
3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft™.
4. Space occupied by circuit breaker is calculated by:
Overall (Height "X" and Width "Y")
Minimum wire bend space (manufacturer specified)
Location "M" from right to left.
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing.
Siemens I-T-EI-T-E - Disconnect Switches (Max-Flex™ Operators)
Fits Enclosure Depth | Amp | Disconnect Height "X" |
Disconnect Width "Y" |
||||
60.13 | 72.13 | Switch | Rating | Fuse Clip | Fuse Class | ||
• | • | MCS603R | 30A | No Fuse | — | 5.52 | 6.13 |
• | • | MCS603R | 30A | 30A-250V | H,K,R | 8.11 | 6.13 |
• | • | MCS603R | 30A | 30A-600V | H,K,R | 10.11 | 6.13 |
• | • | MCS603R | 30A | 30A-600V | J | 8.48 | 6.13 |
• | • | MCS606R | 60A | No Fuse | — | 5.52 | 6.13 |
• | • | MCS606R | 60A | 60A-250V | H,K,R | 7.86 | 6.13 |
• | • | MCS606R | 60A | 60A-600V | H,K,R | 10.38 | 6.13 |
• | • | MCS606R | 60A | 60A-600V | J | 8.36 | 6.13 |
• | • | MCS610R | 100A | No Fuse | — | 7.59 | 7.38 |
• | • | MCS610R | 100A | 100A-250V | H,K,R | 11.85 | 7.38 |
• | • | MCS610R | 100A | 100A-600V | H,K,R | 13.85 | 7.38 |
• | • | MCS610R | 100A | 100A-600V | J | 10.60 | 7.38 |
• | • | MCS620R | 200A | No Fuse | — | 9.00 | 9.17 |
• | • | MCS620R | 200A | 200A-250V | H,K,R | 14.70 | 9.17 |
• | • | MCS620R | 200A | 200A-600V | H,K,R | 17.20 | 9.17 |
• | • | MCS620R | 200A | 200A-600V | J | 13.32 | 9.17 |
Note: Enclosures that are 24.13" deep require a 48" Max-Flex™ cable (minimum cable length). Siemens I-T-E Max-Flex™ Operators (Circuit Breakers)
Complete Operator Mechansim |
Amp Rating | Breaker Frame Size |
Circuit Breaker Height "X" |
Circuit Breaker Width "Y" |
|
Circuit Breaker Type | |||||
FHOE036 | 125A | ED | ED2, ED4, ED6, HED4, HED6 | 6.34 | 3.00 |
FHOE036 | 125A | CED | CED6 | 9.58 | 3.00 |
FHOF036 | 250A | FD | FXD6-A, FD6-A, HFD6, FXD6ETJ, HHFD6, HHFXD6 | 9.50 | 4.50 |
FHOF036 | 250A | CFD | CFD6, CFD6-ETI | 14.25 | 4.50 |
FHOJ036 | 400A, 600A | JD, LD | JXD2, LXD6, JD6, LD6, HJD6, HLD6, HHJD6, HHLD6, HHJXD6, HHLDX6, JXD6-ETI, LXD6-ETI |
11.00 | 7.50 |
FHOJ036 | 400A, 600A | CJD,CLD | CJD6, CLD6, CJD6-ETI, CLD6-ETI | 17.86 | 7.50 |
FHOLMO36 | 800A | LMD | LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI | 16.00 | 9.00 |
FHON048 | 800A, 1200A | MD, ND | MD6, ND6, MXD6, NXD6, HMD6, HND6, HMXD6, HNXD6, CMD6, CND6, MXD6-ETI, CMD6-ETI |
24.00 | 9.00 |
FHONO48 | 1600A, 2000A | PD,RD | PD6, RD6, PXD6, RXD6, HPD6, HRD6, HPXD6, HRXD6, CPD6 |
24.50(2) | 13.63(2) |
Circuit Breaker Size includes required base mounting block.
Last three digits of operator mechanism part number denote cable length in inches.
24" deep enclosures require longer operating cables. Sold separately.
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13
(Deduct 1.45 inches from "K" for FHONO48 Operator mechanism for MD,ND,PD,RD Circuit Breakers)
Space Occupied By Disconnect
1. Siemens I-T-E Max-Flex™ System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex™ cables.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
- Location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing.
Square DSquare D Class 9422 Variable Depth Disconnect Switches
Fits Enclosure Height | Square D Amp Number |
Amp Rating |
Space Occupied | When A=60.13 P |
When A=72.13 P |
|||||
60.13 | 72.13 | Fuse Clip | Fuse Class | L | M | N | ||||
• | • | TCN-30 | 30A | No Fuse | — | 3.80 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TCF-30 | 30A | 30A-250V | H, K, R | 5.53 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TCF-33 | 30A | 30A-600V | H, K, R | 8.15 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TCF-33 | 30A | 60A-250V | H, K, R | 6.15 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TCF-33 | 30A | 30A-600V | J | 5.53 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TDN-60 | 60A | No Fuse | — | 3.80 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TDF-60 | 60A | 30A-600V | H, K, R | 8.15 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TDF-60 | 60A | 60A-250V | H, K, R | 6.15 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TDF-63 | 60A | 60A-600V | H, K, R | 8.65 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TDF-63 | 60A | 60A-600V | J | 5.53 | 6.97 | 0.63 | 6.75 | 12.75 |
• | • | TEN-10 | 100A | No Fuse | — | 3.80 | 6.97 | 0.63 | 6.62 | 12.62 |
• | • | TEF-10 | 100A | 100A-250V | H, K, R | 8.25 | 6.97 | 0.63 | 6.62 | 12.62 |
• | • | TEF-10 | 100A | 100A-600V | H, K, R | 10.25 | 6.97 | 0.63 | 6.62 | 12.62 |
• | • | TEF-10 | 100A | 100A-600V | J | 7.05 | 6.97 | 0.63 | 6.62 | 12.62 |
• | • | TEF-13 | 100A | 200A-600V | J | — | — | 0.63 | 6.62 | 12.62 |
• | • | TC-1 | 30A | No Fuse | ‑ | 5.75 | 6.12 | 0.63 | 5.88 | 11.88 |
• | • | TC-2 | 30A | 30A-250V | H, K, R | 5.75 | 6.12 | 0.63 | 5.88 | 11.88 |
• | • | TC-3 | 30A | 30A-600V | H, K, R | 7.75 | 6.12 | 0.63 | 5.88 | 11.88 |
• | • | TC-3 | 30A | 60A-250V | H, K, R | 5.88 | 6.12 | 0.63 | 5.88 | 11.88 |
• | • | TC-3 | 30A | 30A-600V | J | 5.75 | 6.12 | 0.63 | 5.88 | 11.88 |
• | • | TD-1 | 60A | No Fuse | — | 6.38 | 6.75 | 0.63 | 6.75 | 12.75 |
• | • | TD-2 | 60A | 30A-600V | H, K, R | 8.50 | 6.75 | 0.63 | 6.75 | 12.75 |
• | • | TD-2 | 60A | 60A-250V | H, K, R | 6.50 | 6.75 | 0.63 | 6.75 | 12.75 |
• | • | TD-3 | 60A | 60A-600V | H, K, R | 9.00 | 6.75 | 0.63 | 6.75 | 12.75 |
• | • | TD-3 | 60A | 60A-600V | J | 6.38 | 6.75 | 0.63 | 6.75 | 12.75 |
• | • | TE-1 | 100A | No Fuse | — | 4.75 | 8.50 | 0.63 | 6.50 | 12.50 |
• | • | TE-2 | 100A | 100A-250V | H, K, R | 7.50 | 8.50 | 0.63 | 6.50 | 12.50 |
• | • | TE-2 | 100A | 100A-600V | H, K, R | 9.50 | 8.50 | 0.63 | 6.50 | 12.50 |
• | • | TE-2 | 100A | 100A-600V | J | 6.25 | 8.50 | 0.63 | 6.50 | 12.50 |
• | • | TE-3 | 100A | 200A-600V | J | 13.75 | 8.50 | 0.63 | 6.50 | 12.50 |
• | • | TF-1 | 200A | No Fuse | — | 5.50 | 11.75 | 0.63 | 5.12 | 11.12 |
• | • | TF-2 | 200A | 200A-250V | H, K, R | 11.50 | 11.75 | 0.63 | 5.12 | 11.12 |
• | • | TF-2 | 200A | 200A-600V | H, K, R | 14.00 | 11.75 | 0.63 | 5.12 | 11.12 |
• | • | TF-2 | 200A | 200A-600V | J | 10.12 | 11.75 | 0.63 | 5.12 | 11.12 |
• | • | TF-3 | 200A | 400A-600V | J | 14.50 | 11.75 | 0.63 | 5.12 | 11.12 |
Fits Enclosure Depth | Square D Type Number |
Amp Rating |
Space Occupied | When A=60.13 P |
When A=72.13 P |
||||
60.13 | 72.13 | Frame Size | L | M | N | ||||
• | • | RG-1 | 75A | GJL | 3.53 | 3.87 | 0.63 | 6.69 | 12.69 |
• | • | RG-1 | 100A | GJL | 3.53 | 3.87 | 0.63 | 6.69 | 12.69 |
• | • | RN-1 | 100A | FAL, FHL | 5.12 | 5.38 | 0.63 | 6.88 | 12.88 |
• | • | RP-1 | 250A | KAL, KHL | 7.12 | 5.75 | 0.63 | 7.56 | 13.56 |
• | RR-1 | 400A | LAL, LHL, Q4L | 7.62 | 8.88 | 0.63 | — | 9.25 |
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing.
Square D Class 9422 Disconnect Switches (Cable Mechanism 9422-CFT30 and 9422A-1 Handle Mechanism)Fits Enclosure Depth | Square D Type Number |
Amp Rating |
Fuse Clip | Fuse Class | Disconnect Height "X" |
Disconnect Width "Y" |
|
A=60.13 | A=72.13 | ||||||
P | P | ||||||
• | • | TCN-30 | 30A | No Fuse | — | 5.90 | 6.20 |
• | • | TCF-30 | 30A | 30A-250V | H, K, R | 7.50 | 6.20 |
• | • | TCF-33 | 30A | 30A-600V | H, K, R | 10.15 | 6.20 |
• | • | TCF-33 | 30A | 60A-250V | H, K, R | 8.15 | 6.20 |
• | • | TCF-33 | 30A | 30A-600V | J | 7.50 | 6.20 |
• | • | TDN-60 | 60A | No Fuse | — | 5.90 | 6.20 |
• | • | TDF-60 | 60A | 30A-600V | H, K, R | 10.15 | 6.20 |
• | • | TDF-60 | 60A | 60A-250V | H, K, R | 8.15 | 6.20 |
• | • | TDF-63 | 60A | 60A-600V | H, K, R | 10.65 | 6.20 |
• | • | TDF-63 | 60A | 60A-600V | J | 7.50 | 6.20 |
• | • | TEN-10 | 100A | No Fuse | — | 5.90 | 6.20 |
• | • | TEF-10 | 100A | 100A-250V | H, K, R | 10.35 | 6.20 |
• | • | TEF-10 | 100A | 100A-600V | H, K, R | 10.35 | 6.20 |
• | • | TEF-10 | 100A | 100A-600V | J | 10.35 | 6.20 |
Fits Enclosure Depth | ||||||
A=60.13 | A=72.13 | Circuit Breaker | Circuit Breaker | |||
P | P | Cable Type Switch | Amp Rating | Frame Type | Height "X" | Width "Y" |
• | • | 9422 CGJ30 | 75A | GJL | 4.75 | 3.50 |
• | • | 9422 CEJ30 | 100A | GJL | 4.75 | 3.50 |
• | • | 9422 CFA30 | 100A | FAL,FHL | 6.00 | 4.50 |
• | • | 9422 CKA30 | 250A | KAL,KHL | 8.00 | 4.50 |
• | • | 9422 CLA30 | 400A | LAL,LHL,Q4L | 11.00 | 6.00 |
Use cable mechanism with circuit breaker and 9422-A1 handle mechanism
Cable operators are offered in 3’, 5’, and 10’ lengths. Last 2 digits of part numbers above (30) are for 3’ cables
Space Occupied By Disconnect Switch
1. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism.
2. See National Electrical Code 2005 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.
3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius.
4. Space occupied by circuit breaker is calculated by:
- Overall (Height "X" and Width "Y")
- Minimum wire bend space (manufacturer specified)
"K" = 7.88 when "A" = 60.13
"K" = 13.88 when "A" = 72.13
Charts reference Space Occupied by Disconnect Drawing.